Why Was the Inspection Arranged?
The owner arranged an EICR ahead of refurbishment to understand the condition of the existing electrical installation. Inspection and testing helped identify safety concerns and the electrical improvements to consider before work progresses room by room.
What Did the Inspection Find?
- An ageing consumer unit requiring replacement to improve circuit protection.
- Irregularities in socket circuits, including unexpected ring continuity readings and evidence of previous wiring alterations.
- Earthing and bonding arrangements requiring improvement.
- Electrical equipment exposed to the elements in an area undergoing renovation.
What Did IN-TECH Recommend?
The EICR set out the following remedial recommendations for the planned refurbishment.
- Replace the consumer unit with a modern board incorporating individual RCBO protection, surge protection and spare capacity for future circuits.
- Upgrade the relevant earthing and bonding arrangements.
- Investigate affected socket circuits to locate and correct wiring faults.
- Make exposed electrical equipment safe and provide suitable temporary weatherproof arrangements.
- Review each room’s electrical requirements before renovation moves forward.
What Was the Outcome?
The completed EICR gave the owner an assessment of the existing installation and a practical plan for addressing the findings. Inspecting before renovation allows electrical improvements to be considered alongside the wider refurbishment.